    Hi, I was gifted a Tilley radiator and it’s missing the wire mantle.
    I see that there is a ceramic heater as well.
    My question is, do I need both these parts for the radiator to work or are they two different types of mantle/heater??
    Appreciate any help you give me..
    Davy..
     
  2. Tony Press

    Tony Press Netherlands Subscriber

    Offline
    Joined:
    Aug 28, 2012
    Messages:
    11,101
    Location:
    Stinkpot Bay, Howden, Tasmania, Australia
    David

    Welcome.

    I am not sure what you mean by “ceramic heater”, but take a look here:
    Tilley IF542 (7/1958)

    You will be able to see the steel mantle and a ceramic tube inside. You need both.

    Cheers

    Tony

    @David Moulds
     
  3. David Moulds United Kingdom

    Offline
    Joined:
    May 6, 2020
    Messages:
    12
    Location:
    Belfast
    Hi Tony,
    That’s it, I do need the ceramic as well, Thanks for your help mate..
     
  4. JEFF JOHNSON

    JEFF JOHNSON United Kingdom Subscriber

    Offline
    Joined:
    Nov 28, 2010
    Messages:
    16,892
    Location:
    Shetland Islands UK..
    Welcome aboard!:thumbup:
     
  5. David Shouksmith

    David Shouksmith India Founder Member

    Offline
    Joined:
    Sep 6, 2010
    Messages:
    8,416
    Location:
    North-East England
    Yes, the ceramic tube is vital otherwise the top of the vapouriser will slowly get damaged by the heat - the metal forms flakes which slowly fall off. In fact, this still happens even with the ceramic tube fitted, only much slower...
     
  6. David Moulds United Kingdom

    Offline
    Joined:
    May 6, 2020
    Messages:
    12
    Location:
    Belfast
    Thank you..
     
  7. David Moulds United Kingdom

    Offline
    Joined:
    May 6, 2020
    Messages:
    12
    Location:
    Belfast
    Thanks for that, I noticed the ceramic rod is on the heater, I’ve ordered a new wire mantle and hopefully get it fired up very soon..
    When I received the radiator it had an old material mantle on it, I take it these are the wrong mantles for these heaters..
     
  8. David Shouksmith

    David Shouksmith India Founder Member

    Offline
    Joined:
    Sep 6, 2010
    Messages:
    8,416
    Location:
    North-East England
    No, they're the correct mantles except they were replaced by the later wire mesh type. Unfortunately, the original mantles contained asbestos so you'll need to be careful with it - don't breathe in the dust!! I think (note, think!) you need to seal it in two polythene bags, seal them and phone up your local council for advice. If that's wrong, no doubt someone will tell us. Otherwise Google it...
     
  9. David Moulds United Kingdom

    Offline
    Joined:
    May 6, 2020
    Messages:
    12
    Location:
    Belfast
    Thanks for that David..
    My brother in law worked for Tilley when they were in Belfast, he has a bag of mantles and three lamps for me, I think these ones were probably made in the 80’s or 90’s so hopefully no asbestos in them..
    Thanks for your help..
     
  10. ColinG United Kingdom

    Offline
    Joined:
    Oct 2, 2017
    Messages:
    4,816
    A bag of mantles and three lamps... that'll be a good haul!
     
  11. David Moulds United Kingdom

    Offline
    Joined:
    May 6, 2020
    Messages:
    12
    Location:
    Belfast
    Yes mate, I’ll get a couple of pics up when I get them, he has some of the funnels for filling them and a gas camping stove and heater for me as well. He’s got a load of service kits as well so it’ll keep me busy for a wee while..
     
  12. David Shouksmith

    David Shouksmith India Founder Member

    Offline
    Joined:
    Sep 6, 2010
    Messages:
    8,416
    Location:
    North-East England
    This is the first time ever we've had contact, even vicariously, with anyone who worked at any Tilley factory... :thumbup:
     
  13. David Moulds United Kingdom

    Offline
    Joined:
    May 6, 2020
    Messages:
    12
    Location:
    Belfast
    Yes David, my brother in law worked for them in their Belfast plant for a good 15 years until they closed in 2000, he spray painted the bases.. he got all the parts at cost price, I just wish I had of got more spares from him when he was there..
     
  14. ColinG United Kingdom

    Offline
    Joined:
    Oct 2, 2017
    Messages:
    4,816
    I'd be intrigued to know more about Tilley's painting procedure and what type of paint they used, if he knows.
     
  15. David Moulds United Kingdom

    Offline
    Joined:
    May 6, 2020
    Messages:
    12
    Location:
    Belfast
    I will ask him the next time I’m chatting to him..
     