    I have this Coleman 242c and nothing but air was coming out of the generator, so I took the generator off and there is just barely any fuel like spewing and bubbling out. What’s wrong?
     
  2. Cottage Hill Bill

    Offline
    Joined:
    Sep 5, 2012
    Messages:
    335
    Assuming that the fount is holding pressure, most likely the fuel/air (f/a) tube below the valve is clogged. You will need to remove the valve from the fount, disassemble the f/a tube and clean it. Pay attention to the placement of the spring when reassembling. This diagram should help. Part 242a-148 is the f/a tube assembly.
    https://www.oldcolemanparts.com/diagrams/242B.jpg
     
  3. Levi Tomey United States

    Offline
    Joined:
    Apr 2, 2020
    Messages:
    275
    Location:
    Muncie Indiana USA
    Yeah I cleaned it with an ultrasonic cleaner and then by hand and now it... works. But the mantle is splotchy and not completely lit.
     
  4. JEFF JOHNSON

    JEFF JOHNSON United Kingdom Subscriber

    Offline
    Joined:
    Nov 28, 2010
    Messages:
    16,890
    Location:
    Shetland Islands UK..
    The jet/gas tip on the vapouriser/generator may be enlarged or loose, the vapouriser may need to be taken apart and cleaned.
     
  5. Pancho

    Pancho Subscriber

    Offline
    Joined:
    Nov 26, 2019
    Messages:
    515
    Location:
    México
    Take the F/a out from the fount and take it apart. I clean them in white vinegar
     