    Hi folks, see attached pic. The plunger is forcing itself back out! is doing this after only four strokes so pressure not high. Have changed all the washers etc but no change. Also I’m getting a fuel squirt when plunger reaches it’s furthest point. A492EC8A-1719-4F51-A099-8C5E2AB7D0D5.jpeg

    Ideas please?
     
    Last edited by a moderator: Sep 7, 2020
  2. plantpot United Kingdom

    Offline
    Joined:
    Aug 2, 2019
    Messages:
    243
    Location:
    London
    @John Taylor

    Non Return Valve at the bottom of the pump is not sealing. Did you change the seal in it for a new one?

    If you did then undo it and make sure the mating sufaces are spotlessly clean and the rubber is not damaged and replace. It should work unless you have assembled the NRV wrong.