Aida foot valve - leaking after fixing

Discussion in 'Fettling Forum' started by elcarlstono, Nov 15, 2022.

  1. elcarlstono United States

    Offline
    Joined:
    Nov 15, 2022
    Messages:
    3
    Location:
    USA - North Carolina
    Unsurprisingly my AIDA 1500 had a leaky foot valve when I got it; fuel seeping from the top of the generator. What perplexes me is that it is still doing this after replacing with a new viton seal. What else can I check for with this issue?
    Thanks.
     
  2. JEFF JOHNSON

    JEFF JOHNSON United Kingdom Subscriber

    Offline
    Joined:
    Nov 28, 2010
    Messages:
    16,412
    Location:
    Shetland Islands UK..
    Welcome aboard!:thumbup:
    The Aida and other lanterns of that genre, do not have a positive shut off valve, the knob simply operates the pricker rod, so it's best to use the soft start method.
     
  3. bp4willi

    bp4willi Germany Subscriber

    Offline
    Joined:
    Jan 21, 2014
    Messages:
    1,154
    Location:
    Niers, Germany
    @elcarlstono
    Pls check if the fuel pickup tube has a crack.

    Also check in detail, if/why the valve might be leaking. Maybe the rim, onto whicht the rubber pip is pushed, has a scratch
     
  4. elcarlstono United States

    Offline
    Joined:
    Nov 15, 2022
    Messages:
    3
    Location:
    USA - North Carolina
    What's the fun in that? I have the reason I got this lantern was for the torch preheat function. But I appreciate the advice.

    Good suggestion. I'll give it a thorough inspection shortly.
     
  5. elcarlstono United States

    Offline
    Joined:
    Nov 15, 2022
    Messages:
    3
    Location:
    USA - North Carolina
    I got it sorted out. I pulled the valve and the seal for the foot valve had a "wrinkle" in it, so I replaced it, and its holding fine. Also Ibeleive the last time I shut down I turned the knob instead of bleeding pressure which may have contributed. THanks!
     