    Has anyone ever removed the pump tube from a Coleman slant fount?

    I need to fix a leak from the bottom of the pump tube, not caused by the check valve, or it’s direct fitting, but most likely by a failure of the join between the pump tube proper and the base of the pump tube.

    All advice greatly appreciated.


    Tony
     
  2. JEFF JOHNSON

    JEFF JOHNSON United Kingdom Subscriber

    Offline
    Joined:
    Nov 28, 2010
    Messages:
    16,892
    Location:
    Shetland Islands UK..
  3. Tony Press

    Tony Press Netherlands Subscriber

    Offline
    Joined:
    Aug 28, 2012
    Messages:
    11,101
    Location:
    Stinkpot Bay, Howden, Tasmania, Australia
    Yes, he may.

    I’m hoping to do as little as I need to to fix the problem.

    I’m pondering a Carswell’s solution also.

    Tony
     
  4. Toby Garner

    Toby Garner United States Subscriber

    Offline
    Joined:
    Jun 13, 2021
    Messages:
    478
    Location:
    SW Missouri
    Tony, removing the pump will be a difficult task as they have a snorkel tube extending towards the top of the fount... I believe these were placed from inside the fount before the bottom was crimped and soldered in place... Hopefully I'm wrong :)
     
  5. Tony Press

    Tony Press Netherlands Subscriber

    Offline
    Joined:
    Aug 28, 2012
    Messages:
    11,101
    Location:
    Stinkpot Bay, Howden, Tasmania, Australia
    The pump tube certainly has the snorkel. The fount also has the “captured” pickup tube for the fuel (ie no pickup tube fixed to the fuel valve).

    That makes treating the leak with Carswell's from inside the fount difficult. I’m now pondering treating the bottom of the pump tube with Carswell’s from inside the pump tube itself.

    The fount is in good condition and I’m very unlikely to find another like this, with that date, in Australia.

    I’m going to try to get some photos of the leak “down the pump tube” later today.

    Tony

    @Toby Garner
     
  6. Toby Garner

    Toby Garner United States Subscriber

    Offline
    Joined:
    Jun 13, 2021
    Messages:
    478
    Location:
    SW Missouri
    Tony if it's a "slant" fount the F/A tube is removable (internal pump 427's were soldered into the fount), however it would still be very difficult to cover the bottom section of the pump without wasting a lot of sealer... I've seen others seal them from inside the pump bore, although I've also seen them get sealer in the check valve area and cause another issue.
     
  7. Tony Press

    Tony Press Netherlands Subscriber

    Offline
    Joined:
    Aug 28, 2012
    Messages:
    11,101
    Location:
    Stinkpot Bay, Howden, Tasmania, Australia
    It’s an internal pump 427 by the looks.

    I will get photos up later.

    Tony
     