Primus 1020 Pump NRV thread?

Discussion in 'Fettling Forum' started by Weirdnerd, Jan 10, 2015.

  1. Weirdnerd

    Offline
    Joined:
    Sep 17, 2012
    Messages:
    138
    Finally I found out why my Primus 1020 was leaking pressure, the threads of the pump tube to accept the NRV are different than the correct NRV housing, does anybody knows what is the thread size and pitch?...

    1420931614-Valve_1.jpg 1420931626-Valve_2.jpg 1420931639-Valve_3.jpg 1420931650-Valve_4.jpg
     

    Attached Files:

  2. conny Sweden

    Offline
    Joined:
    Jan 1, 2011
    Messages:
    11
    Location:
    Sweden
    M8x0.75
     
  3. Weirdnerd

    Offline
    Joined:
    Sep 17, 2012
    Messages:
    138
    Thanks Conny!...will see if I can find it today.
     
  4. longilily United Kingdom

    Offline
    Joined:
    Jan 25, 2011
    Messages:
    1,450
    Location:
    Dungeness
    M8 x 0.75 are cheap enough over here , around £5 for the cheaper CS taps/dies ( which is fine for cutting brass )

    Hope you get sorted [-o<

    Cheers
     
  5. Weirdnerd

    Offline
    Joined:
    Sep 17, 2012
    Messages:
    138
    My local hardware store was closed, so I will check tomorrow.... small towns have their quirks.
     
  6. Afterburner

    Offline
    Joined:
    Aug 19, 2014
    Messages:
    107
    I would believe that M8*0,75 is closest that you can buy easily. Maybe correct is 8mm and 34 tpi since standard metric threads were not there when they started to make these type of NRVs' more that 100 years ago. :-k

    Couple of years ago I needed to drill out NRV from one Primus No. 5 stove (1934). I made new thread with M8*0,75 tap. To turn NRV into that thread needed some force from the beginning. :doh: I made M8*0,75 thread to a piece of steel and I made sure that thread is perfect. To turn NRV into that thread also needed some force from the beginning. I took NRV out and saw that treads of it had deformed a little bit. So the threads were not exact match. Maybe thread angle in NRV is 55° or pitch was not exactly 0,75mm.

    Maybe after you get thread done to the pump tube do a same thread to a piece of steel and turn NRV to that thread first. That would deform NRV thread to M8*0,75 and it's easier to get into the thread in pump tube. Also removal of NRV will be easier if it's needed some day because threads are having better match.
     
  7. Weirdnerd

    Offline
    Joined:
    Sep 17, 2012
    Messages:
    138
    Thanks Afterburner, will do that, it is better to know from the start than to learn from the mistakes.
     

Share This Page