Handi Kero-Pet

Discussion in 'Handi' started by ROBBO55, Nov 15, 2017.

  1. ROBBO55

    ROBBO55 Subscriber

    Offline
    Joined:
    Oct 21, 2014
    Messages:
    4,464
    Location:
    Somersby, New South Wales, Australia
    G’day, Here is my recently fettled Kero-Pet lantern with a grey hood. This lantern is fitted with a jet and a steel spring only within the generator for running on kerosene (no brass gauze).

    The name plate is all brass with red background.

    The attachments for the tripod style burner frame to the base plate are a flared fitting and not removable. The flame spreader is a separate piece fitted with a pressed metal screen and screwed onto the cast brass mixing tube. The frame has no stamp marks

    Note on the shutoff, although the shaft is threaded and screwed into a brass nut moulded into the Bakelite knob it is also pinned. If you had to replace the gland packing it would make it difficult. The gland packing is fibre washers.

    The base plate is nickel plated steel and collar is painted steel. Both were treated for rust with rust converter and then painted aluminium high temp paint.

    The globe is not branded but shows sign of age. So I believe it is original.

    1.JPG

    1.JPG 2.JPG 3.JPG 4.JPG 6.JPG 5.JPG 8.JPG 7.JPG 9.JPG 11.JPG 10.JPG 13.JPG 12.JPG 15.JPG 16.JPG 17.JPG 18.JPG 20.JPG 14.JPG
    23.JPG 21.JPG 22.JPG 24.JPG
     
    Last edited: Nov 15, 2017
  2. ROBBO55

    ROBBO55 Subscriber

    Offline
    Joined:
    Oct 21, 2014
    Messages:
    4,464
    Location:
    Somersby, New South Wales, Australia
    Back in working order.

    I used a Coleman 21 mantle during the test firing. The lantern is bright but there is a very audible pulsing noise with the control cock fully open. It was not so obvious visually. The pulse was reduced by backing off with the shutoff control cock setting. This was also a characteristic of the previous Handi lantern I have.

    25.JPG 26.JPG 27.JPG 28.JPG 29.JPG
     
  3. Tony Press

    Tony Press Australia Subscriber

    Offline
    Joined:
    Aug 28, 2012
    Messages:
    11,105
    Location:
    Stinkpot Bay, Howden, Tasmania, Australia
    Great job, @ROBBO55! And a fine set of photos.

    If I recall correctly, the red label was for kerosene; the blue for gasoline (petrol).

    Cheers

    Tony
     
  4. JEFF JOHNSON

    JEFF JOHNSON United Kingdom Subscriber

    Offline
    Joined:
    Nov 28, 2010
    Messages:
    16,930
    Location:
    Shetland Islands UK..
    A fine example!:thumbup:
     
  5. ROBBO55

    ROBBO55 Subscriber

    Offline
    Joined:
    Oct 21, 2014
    Messages:
    4,464
    Location:
    Somersby, New South Wales, Australia
    Thanks Jeff and Tony. Yes, this is the kerosene / paraffin version.
     
  6. kero-scene Australia

    Offline
    Joined:
    Jan 23, 2013
    Messages:
    365
    Location:
    Australia
    On mine the thread goes further up and the brass collar simply screws off allowing the fibre washers to be changed.

    Thanks for the pics showing how this particular mantle works with a Handi.
     
  7. kero-scene Australia

    Offline
    Joined:
    Jan 23, 2013
    Messages:
    365
    Location:
    Australia
    Following up on mantle choice, some people won't use Coleman mantles in a Handi because of the fine weave. Old style Chinese made Butterfly mantles are thought better, Aussie 'S2' gas mantles are also OK.
     
  8. ROBBO55

    ROBBO55 Subscriber

    Offline
    Joined:
    Oct 21, 2014
    Messages:
    4,464
    Location:
    Somersby, New South Wales, Australia
    Thanks @kero-scene for the information. I'll have to check the shaft, thread and collar next time I have them apart.

    I have tried Anchor mantles and found the Coleman better but haven't tried Butterfly. I have some 'S2' mantles so will give them a try. I also have some Peerless 22A mantles on order to see how they perform when they arrive.
     

Share This Page