Optimus 1550 problems.

Discussion in 'Pressure Lamp Discussion Forum' started by Dwight, Dec 21, 2018.

  1. Dwight Canada

    Offline
    Joined:
    Dec 21, 2018
    Messages:
    1
    Location:
    Burnaby, BC, Canada
    Just recently picked up a 1550 500cp lantern. I cleaned everything up on it. Now that it's back together I would like to light it. But I'm not able to pressurize the fount. I replaced the leather pump cup. So what's going on? Sticky air valve? Coleman has a check valve and air screw rod that you can open and close but this doesn't have that. Solutions. Please
     
  2. Nils Stephenson

    Nils Stephenson Founder Member

    Offline
    Joined:
    Sep 9, 2010
    Messages:
    3,340
    Location:
    Copenhagen, Denmark
    Is there resistance when you pump? As you would normally expect when pushing air through the valve. If not, does the pump leather fit snugly in the pump tube and is it well oiled?
    If there is resistance, does it feel (and sound) like there is air getting through the valve or does it 'lock solid'? If so, is the pump rod pushed out again by air pressure indicating a leaky NRV.
    Have you closed the pressure release screw on the filler cap?

    That should be a good start. We need to localise where the fault could be.
     
  3. KAB

    KAB Subscriber

    Offline
    Joined:
    Mar 27, 2016
    Messages:
    493
    Location:
    South East England
    Time to give it a bath and check for bubbles
     